YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
n3-14
(0532)
Expert
OEB High Frequency Injection
Sets the function that injects harmonic signals during overexcitation deceleration.
0
(0, 1)
Enable this parameter to set a shorter deceleration time.
If you frequently use overexcitation deceleration on a motor, the motor loss will increase the risk of burn damage.
When you set this parameter to 1, the motor can make a loud excitation sound during overexcitation deceleration. If the excitation sound is unwanted, set this parameter to 0 to disable the function.
The drive injects harmonic signals at the time of overexcitation deceleration. You can decrease the deceleration time because motor loss increases.