No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
n4-62
(1B82)
|
Regen Low Speed Comp Gain
|
       
Sets a compensation gain to improve the control qualities for regenerative loads in the low speed range.
|
100.0 %
(50.0 - 500.0%)
|
Note:
If you do not apply a regenerative load when you operate at low speeds, do stationary Auto-Tuning for Line-to-Line Resistance only. If this does not make it better, increase the setting value in 5% increments. The recommended setting is 100% to 150%. If you set this parameter too high, the drive will detect CF [Control Fault] at stop.