Jump to main content

n4-62: Regen Low Speed Comp Gain

No.

(Hex.)

Name

Description

Default

(Range)

n4-62

(1B82)

Regen Low Speed Comp Gain

Sets a compensation gain to improve the control qualities for regenerative loads in the low speed range.

100.0 %

(50.0 - 500.0%)

Note:

If you do not apply a regenerative load when you operate at low speeds, do stationary Auto-Tuning for Line-to-Line Resistance only. If this does not make it better, increase the setting value in 5% increments. The recommended setting is 100% to 150%. If you set this parameter too high, the drive will detect CF [Control Fault] at stop.