No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
n4-67
(1B87)
|
Estimate Gain Switchover Freq
|
       
Sets the switching frequency for estimation gain for these parameters: n4-63 [Speed EstimateResponse@High Freq]n4-64 [Speed Estimate Response@Low Freq]n4-65 [Flux Estimate Response@High Freq]n4-66 [Flux Estimate Response @Low Freq] Usually it is not necessary to change this setting.
|
6.00 Hz
(0.00 - E1-04 setting)
|
When the output frequency ≥ n4-67, the drive will select n4-63 and n4-65. When the output frequency < n4-67, the drive will select n4-64 and n4-66.