No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
n4-73
(1B8D)
|
PGo Recovery Selection
|
       
Sets the restart mode to Without Encoder Mode or the With Encoder Mode when an encoder is disconnected.
|
0
(0, 1)
|
Set A1-02 = 4 [Control Method Selection = AOLV] and n4-72 = 1 [Speed Feedback Mode = With Encoder] to use this parameter.
Parameter F1-02 [Encoder Signal Loss Detect Sel] sets the drive response when the drive detects a disconnected encoder. This parameter sets the drive to start up in the Without Encoder Mode or With Encoder Mode if the drive detects PGo [Encoder (PG) Feedback Loss].
Note:
A PG-B3 encoder option is necessary to use this parameter. When you use a PG-X3 option, it is not necessary to set this parameter.
If the drive detects PGo, de-energize the drive and examine the wiring for the encoder.
- 0
- Without Encoder
-
- 1
- With Encoder
-