No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
n4-74
(1B8E)
|
Limit of Flux Loop
|
       
Sets the control level for flux loop control output.
|
250%
(100 - 500%)
|
If the torque is not sufficient because of 100% or more loads, increase the setting value in 20% increments. If the setting is too high, overexcitation could occur and overheat the motor.