No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
n8-01
(0540)
Expert
|
Pole Position Detection Current
|
       
Sets the Initial Rotor Position Estimated Current as a percentage where E5-03 [PM Motor Rated Current (FLA)] = 100%. Usually it is not necessary to change this setting.
|
50%
(0 - 100%)
|
The drive uses the Initial Rotor Position Estimated Current to detect the initial position of rotors.
Use the "Si" value on the motor nameplate, if available.