Jump to main content

n8-01: Pole Position Detection Current

No.

(Hex.)

Name

Description

Default

(Range)

n8-01

(0540)

Expert

Pole Position Detection Current

Sets the Initial Rotor Position Estimated Current as a percentage where E5-03 [PM Motor Rated Current (FLA)] = 100%. Usually it is not necessary to change this setting.

50%

(0 - 100%)

The drive uses the Initial Rotor Position Estimated Current to detect the initial position of rotors.

Use the "Si" value on the motor nameplate, if available.