Jump to main content

14: User-Set Speed Agree 2

Setting Value

Function

Description

14

User-Set Speed Agree 2

The terminal activates when the output frequency is in the range of L4-03 [Speed Agree Detection Level (+/-)] ± L4-04 [Speed Agree Detection Width (+/-)] and in the range of the frequency reference ± L4-04.

Note:
  • The detection level set in L4-03 is a signed value. The drive will only detect in one direction.

  • The drive outputs the motor speed status when A1-02 = 3, 7 [Control Method Selection = CLV, CLV/PM].

ON
The output frequency is in the range of “L4-03 ± L4-04” and the range of frequency reference ± L4-04.
 
OFF
The output frequency is not in the range of “L4-03 ± L4-04” or the range of frequency reference ± L4-04.
 
Figure 1. Example of User-set Speed Agree 2 (L4-03 Is Positive)