n8-48: Pull-in/Light Load Id Current

No.

(Hex.)

Name

Description

Default

(Range)

n8-48

(053B)

Pull-in/Light Load Id Current

Sets the d-axis current that flows to the motor during run at constant speed as a percentage where E5-03 [PM Motor Rated Current (FLA)] = 100%.

30%

(20 - 200%)

Adjust in the following situations.

  • Slightly reduce this value if there is too much current when driving a light load at a constant speed.

  • Increase the setting value in steps of 5% when hunting or vibration occurs during run at constant speed.

  • Increase the setting value in steps of 5% if the motor stalls during run at constant speed.