Jump to main content

n8-74: Light Load Iq Level

No.

(Hex.)

Name

Description

Default

(Range)

n8-74

(05C3)

Expert

Light Load Iq Level

Set n8-48 [Pull-in/Light Load Id Current] to the percentage of load current (q-axis current) that you will apply, where E5-03 [PM Motor Rated Current (FLA)] = a setting value of 100%.

30%

(0 - 255%)

Note:
  • If n8-74 > n8-75 [Medium Load Iq Level (low)], the drive will detect oPE08 [Parameter Selection Error].

  • The change is linear between n8-74 and n8-75 and the level of the pull-in current from n8-48 to n8-78 [Medium Load Id Current].