5: Accel/Decel Time Gain

Setting Value

Function

Description

5

Accel/Decel Time Gain

Enters a signal to adjust the gain used for C1-01 to C1-08 [Acceleration/Deceleration Times 1 to 4] and C1-09 [Fast Stop Time] when the full scale analog signal (10 V or 20 mA) is 100%.

When you enable C1-01 [Acceleration Time 1], the acceleration time is:

Acceleration Time 1 = Setting value of C1-01 × acceleration and deceleration time gain / 100

Figure 1. Acceleration/Deceleration Time Gain through Analog Input