Jump to main content

o1-24 to o1-35: Custom Monitor 1 to 12

No.

(Hex.)

Name

Description

Default

(Range)

o1-24 to o1-35

(11AD - 11B8)

RUN

Custom Monitor 1 to 12

Sets a maximum of 12 monitors (Ux-xx) as user monitors. This parameter is only available when you use an LCD keypad.

o1-24: 101

o1-25: 102

o1-26: 103

o1-27 to o1-35: 0

(0, 101 - 9999)

These parameters save the monitor items selected by the LCD keypad [Custom Monitor].

Note:
  • Set the x-xx part of the Ux-xx [Monitor]. For example, set o1-24 = 102 to monitor U1-02 [Output Frequency].

    When the x part of Ux is a letter, replace the letter (hexadecimal number) with a decimal number. For example, set o1-24 = 1301 to monitor Ud-01.

  • You can show a maximum of three selected monitors on one LCD keypad screen.

    • When you select only one monitor, the text size of this monitor increases. For example, when o1-25 to o1-35 = 0, the text size of the monitor saved in o1-24 increases.

    • When you select two monitors, the text size of these monitors increase.

    • When you select four or more monitors, the keypad shows the fourth monitor and all additional monitors on the next screens.

  • You can show monitors selected with o1-24 to o1-26 as a bar graph, analog gauge, or trend plot.

    • Bar graph display: 3 monitors maximum

      Select with o1-24, o1-25, and o1-26.

    • Analog gauge display: 1 monitor

      Select with o1-24.

    • Trend plot display: 2 monitors

      Select with o1-24 and o1-25.

  • You can only set parameters o1-24 to o1-26 with analog output monitors.

  • You can set all monitors to parameters o1-27 to o1-35.