Jump to main content

H4-02: Terminal FM Analog Output Gain

No.

(Hex.)

Name

Description

Default

(Range)

H4-02

(041E)

RUN

Terminal FM Analog Output Gain

Sets the gain of the monitor signal that is sent from MFAO terminal FM.

100.0%

(-999.9 - +999.9%)

The analog signal output from the FM terminal is a maximum of ±10 V (or 20 mA). Select the signal level with H4-07 [Terminal FM Signal Level Select].