o4-09
(0525)
|
IGBT Maintenance Setting
|
       
Sets the U4-07 [IGBT Maintenance] monitor value.
|
0%
(0 - 150%)
|
When you replace a drive, set o4-09 = 0 to reset U4-07. When the o4-09 setting changes, the count of U4-07 starts again as specified by the setting of o4-09. After you complete the configuration, o4-09 automatically resets to 0.
Note:
The maintenance period changes for different operating environments.