YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
o5-19
(1E86)
RUN
Trigger Condition
Sets the condition with which to detect the trigger. This parameter is only available when you use an LCD keypad.
0
(0, 1)
Digital trigger: The drive detects the trigger when the digital trigger target switches from OFF to ON.
Analog trigger: The drive detects the trigger when the analog trigger target changes from “less than” to “equal or more than” the trigger level set in o5-18 [Analog Trigger Level].
Digital trigger: The drive detects the trigger when the digital trigger target switches from ON to OFF
Analog trigger: The drive detects the trigger when the analog trigger target changes from “equal to or more than” to “less than” the trigger level set in o5-18 [Analog Trigger Level].