No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
T1-03
(0703)
|
Motor Rated Voltage
|
       
Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output motors.
|
Determined by o2-04, C6-01
(200 V Class: 0.0 - 255.5 V, 400 V Class: 0.0 - 511.0 V)
|
If you do Auto-Tuning on a drive-dedicated motor or a specialized motor for vector control, the voltage or frequency can be lower than that of a general-purpose motor. Always compare the data from the nameplate or test report with the Auto-Tuning results and check for differences. Enter the voltage necessary to operate the motor in no-load conditions at rated speed for better control precision around rated speed. If the motor test report or the motor nameplate is not available, enter approximately 90% of the motor rated voltage.
If the drive input power supply voltage is low, enter approximately 90% of the input voltage. When the input power supply voltage is low, the current will increase. Make sure that the main power supply capacity is correct and use a molded-case circuit breaker for the drive.