Jump to main content

T1-05: Motor Base Frequency

No.

(Hex.)

Name

Description

Default

(Range)

T1-05

(0705)

Motor Base Frequency

Sets the base frequency (Hz) of the motor.

60.0 Hz

(0.0 - 590.0 Hz)

When Auto-Tuning is carried out, the value of T1-05 is set to E1-04 [Maximum Output Frequency]. If T1-05 < 40 Hz, E1-04 = 40 Hz. If you operate the drive at a speed that is higher than the base frequency, or if you operate in the field weakening range, set E1-04 (E3-04 for motor 2) to the maximum output frequency after you complete Auto-Tuning.