No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
T2-02
(0751)
|
PM Motor Code Selection
|
       
When the drive is operating a Yaskawa PM motor from the SMRA, SSR1, or SST4 series, enter the PM motor code as specified by the rotation speed and motor output.
|
Determined by A1-02 and o2-04
(0000 - FFFF)
|
Enter the motor code in this parameter to automatically set parameters T2-03 to T2-14. When you are operating a specialized motor or a non-Yaskawa motor, set this parameter to FFFF and enter the data from the motor nameplate or the motor test report.
You can only enter the permitted PM motor codes. Different drive control methods will accept different PM motor codes.