Jump to main content

T2-13: Back-EMF Units Selection

No.

(Hex.)

Name

Description

Default

(Range)

T2-13

(0755)

Back-EMF Units Selection

Sets the units that the drive uses to set the induced voltage constant.

1

(0, 1)

0
mV/(rev/min)
 
1
mV/(rad/s)
 
Note:
  • When T2-13 = 0, the drive will use E5-24 [PM Back-EMF L-L Vrms (mV/rpm)] and will automatically set E5-09 [PM Back-EMF Vpeak (mV/(rad/s))] = 0.0.

  • When T2-13 = 1, the drive will use E5-09 and will automatically set E5-24 = 0.0.