Jump to main content

T3-04: System Response Frequency

No.

(Hex.)

Name

Description

Default

(Range)

T3-04

(0763)

System Response Frequency

This parameter uses the load inertia value from the Inertia Tuning process to automatically calculate and set C5-01 [ASR Proportional Gain 1].

10.0 Hz

(0.1 - 50.0 Hz)

If this input value is too high, it can cause oscillation.