No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
T1-12
(0BDB)
|
Test Mode Selection
|
       
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate the motor with a light load attached after Stationary Auto-Tuning is complete, enable this parameter.
|
0
(0, 1)
|
- 0
- No
-
- 1
- Yes
-
After Auto-Tuning, the drive automatically sets E2-02 [Motor Rated Slip] and E2-03 [Motor No-Load Current] when you operate the motor for the first time in Drive Mode.
Note:
After Auto-Tuning is complete and you set the drive to Drive Mode, operate the motor in these conditions:
-
Make sure that you connect all wiring between the drive and motor
-
Make sure that a mechanical brake on the motor shaft is not locked
-
Keep the motor-load ratio at 30%
-
Hold constant speed for longer than 1 second at a minimum of 30% of the speed set in E1-06 [Base Frequency] (the default setting is the same as the maximum frequency).