Input Power Supply Voltage
|
The voltage of the input power supply must be:
Single-phase 200 V class: single-phase 200 Vac to 240 Vac 50/60 Hz, 270 Vdc to 340 Vdc
Three-phase 200 V class: three-phase 200 Vac to 240 Vac 50/60 Hz, 270 Vdc to 340 Vdc
Three-phase 400 V class: three-phase 380 Vac to 480 Vac 50/60 Hz, 513 Vdc to 679 Vdc
|
|
Correctly wire power supply input terminals R/L1, S/L2, and T/L3, or L and N.
|
|
Correctly ground the drive and motor.
|
|
Connection between Drive Output Terminals and Motor Terminals
|
Make sure that you connected drive output terminals U/T1, V/T2, and W/T3 in the correct sequence to align with motor terminals U, V, and W and tighten the screws to a correct tightening torque.
|
|
Control Circuit Terminal Wiring
|
Make sure that you connected the drive control circuit terminals in the correct sequence to align with devices and switches and tighten the screws to a correct tightening torque.
|
|
Control Circuit Terminal Status
|
Turn OFF the inputs from all devices and switches connected to the drive control circuit terminals.
|
|
Connection between Machinery and Motor
|
Disengage all couplings and belts that connect the motor and machinery.
|