You can save a backup of the drive parameters to the keypad. The keypad can store parameter setting values for a maximum of four drives in different storage areas. Backups of the parameter settings can save time when you set parameters after you replace a drive. When you set up more than one drive, you can copy the parameter settings from a drive that completed a test run to the other drives.

Note:
  • Stop the motor before you back up parameters.

  • The drive will not accept a Run command while it makes a backup.

  • The DriveWorksEZ PC software password is necessary to back up qx-xx [DriveWorksEZ Parameter] and rx-xx [DWEZ Connection Parameter]. If you enter an incorrect password, the drive detects PWEr [DWEZ Password Missmatch].

  1. Push [F2 Key] (Home) to show the HOME screen.
    Note:
    • When the drive is in HOME Mode, the screen shows [Home] in the upper right-hand corner of the screen.

    • If [Home] is not shown on [F2 Key], push [F1 Key] (Back) to show [Home] on [F2 Key].

  2. Push [F2 Key] (Menu).
  3. Push [Up arrow key] or [Down arrow key] to select [Parameter Backup/Restore], then push [ENTER Key].
  4. Push [Up arrow key] or [Down arrow key] to select the items to back up, then push [ENTER Key].
  5. Push [Up arrow key] or [Down arrow key] to select [Backup (drive → keypad)], then push [ENTER Key].
  6. Push [Up arrow key] or [Down arrow key] to select a memory location, then push [ENTER Key].

The keypad shows “End” when the backup procedure completes successfully.