Sub-Chart A-2 gives the basic steps to start up the drive for a PM motor.
Note:
-
Although Auto-Tuning will set parameters for speed control with an encoder, set F1-05 [PG 1 Rotation Selection] before starting Auto-Tuning.
-
If you replace the encoder, do Z Pulse Offset Tuning.
| Warning |
|
Crush Hazard
Test the system to make sure that the drive operates safely after you wire the drive and set parameters.
If you do not test the system, it can cause damage to equipment or serious injury or death.
|
Figure 1. PM Motor Auto-Tuning and Test Run Procedure
1
For Yaskawa PM motors (SMRA-series, SSR1-series, or SST4-series), set E5-01 [PM Motor Code Selection]. For PM motors from a different manufacturer, set E5-01 = FFFF.
2
Be sure to release the holding brake before doing Inertia Tuning.
3
In ASR Tuning, the drive will automatically tune Feed Forward control and KEB Ride-Thru 2 parameters.