The procedure in this section shows how to set the trigger for data logging.

Note:

This setting is available only when you select short-term data log as the data log type.

  1. Push [F2 Key] (Home) to show the HOME screen.
    Note:
    • When the drive is in HOME Mode, the screen shows [Home] in the upper right-hand corner of the screen.

    • If the screen does not show [Home] for [F2 Key], push [F1 Key] (Back) and then push [F2 Key] to show [Home].

  2. Push [F2 Key] (Menu).
  3. Push [Up arrow key] or [Down arrow key] to select [Diagnostic Tools], then push [ENTER Key].
  4. Push [Up arrow key] or [Down arrow key] to select [Data Logger], then push [F3 Key] (Setup).
  5. Push [Up arrow key] or [Down arrow key] to select [Log Trigger], then push [ENTER Key].
  6. Push [Up arrow key] or [Down arrow key] to select [Trigger Type Selection], then push [ENTER Key].
  7. Push [Up arrow key] or [Down arrow key] to select the type of trigger, then push [ENTER Key].
    Note:

    There are no detection width or detection time settings for the analog trigger in the data log function. If variations in the analog signal are a problem, select the digital trigger and use o5-16 = 66/67 [Digital Trigger Object = Comparator 1/2]. Use H2-20 [Comparator 1 Monitor Selection] to H2–32 [Comparator 1 Filter Time] to set the conditions for the comparator function.

  8. Push [Up arrow key] or [Down arrow key] to select [Trigger Object], then push [ENTER Key].
  9. Push [Up arrow key] or [Down arrow key] to select the trigger target, then push [ENTER Key].
    Note:

    If analog trigger is the trigger type, set the trigger target and trigger level.

  10. Push [Up arrow key] or [Down arrow key] to select [Trigger Condition], then push [ENTER Key].
  11. Push [Up arrow key] or [Down arrow key] to select the trigger detections, then push [ENTER Key].
  12. Push [Up arrow key] or [Down arrow key] to select [Pre-Trigger Setting], then push [ENTER Key].
  13. Push [LEFT Key] or [RIGHT Key] then push [Up arrow key] or [Down arrow key] to change the value.
  14. After you change the value, push [ENTER Key].

The procedure to set the trigger is complete.