YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
n5-01
(05B0)
Feed Forward Control Selection
Sets the feed forward function.
0
(0, 1)
Details
n5-02
(05B1)
Motor Inertia Acceleration Time
Sets the length of time for the motor to accelerate from the stopped to the maximum frequency with a single motor at the rated torque. Inertia Tuning automatically sets the motor acceleration time.
Determined by C6-01, E5-01, and o2-04
(0.001 - 10.000 s)
n5-03
(05B2)
Feed Forward Control Gain
Sets the ratio between load inertia and motor inertia. Inertia Tuning automatically sets the Feedforward Control Gain value.
1.00
(0.00 - 100.00)
n5-04
(05B3)
RUN
Expert
Speed Response Frequency
Sets the response frequency for the speed reference. Usually it is not necessary to change this parameter.
Determined by A1-02
(0.00 - 500.00 Hz)