Jump to main content

Three-Phase 400 V Class

 

No. 1

Name

Unit

Default

-

Drive Model

-

4001

4002

4004

4005

C6-01

Normal / Heavy Duty Selection

-

HD

ND

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

0

1

o2-04

Drive Model (KVA) Selection

Hex.

91

92

93

94

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

0.2

0.4

0.4

0.75

0.75

1.5

1.5

2.2

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

100

100

b3-06

Speed Estimation Current Level 1

-

1.0

1.0

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

1000

1000

1000

1000

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

713.8

576.4

576.4

447.4

447.4

338.8

338.8

313.6

C6-02

Carrier Frequency Selection

-

3

7

3

7

3

7

3

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

0.6

1

1

1.6

1.6

3.1

3.1

4.2

E2-02

(E4-02)

Motor Rated Slip

Hz

2.5

2.9

2.9

2.6

2.6

2.5

2.5

3

E2-03

(E4-03)

Motor No-Load Current

A

0.4

0.6

0.6

0.8

0.8

1.4

1.4

1.5

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

83.94

38.198

38.198

22.459

22.459

10.1

10.1

6.495

E2-06

(E4-06)

Motor Leakage Inductance

%

21.9

18.2

18.2

14.3

14.3

18.3

18.3

18.7

E2-10

(E4-10)

Motor Iron Loss

W

12

14

14

26

26

53

53

77

E5-01

PM Motor Code Selection

-

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

L2-03

Minimum Baseblock Time

s

0.2

0.2

0.2

0.3

0.3

0.4

0.4

0.5

L2-04

Powerloss V/f Recovery Ramp Time

s

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

L2-05

Undervoltage Detection Lvl (Uv1)

-

380

380

380

380

380

380

380

380

L3-02

Stall Prevent Level during Accel

%

150

120

150

120

150

120

150

120

L3-06

Stall Prevent Level during Run

%

150

120

150

120

150

120

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.178

0.178

0.178

0.142

0.142

0.166

0.166

0.145

L8-02

Overheat Alarm Level

°C

120

120

120

120

105

105

90

90

L8-09

Output Ground Fault Detection

-

0

0

0

0

0

0

0

0

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

10

10

10

n3-02

HSB Current Limit Level

%

150

120

150

120

150

120

150

120

n5-02

Motor Inertia Acceleration Time

s

0.178

0.178

0.178

0.142

0.142

0.166

0.166

0.145

 
 

No. 1

Name

Unit

Default

-

Drive Model

-

4007

4009

4012

4018

C6-01

Normal / Heavy Duty Selection

-

HD

ND

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

0

1

o2-04

Drive Model (KVA) Selection

Hex.

95

96

97

99

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

2.2

3.0

3.0

3.7

4.0

5.5

5.5

7.5

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

100

100

b3-06

Speed Estimation Current Level 1

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

1000

1000

1000

1000

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

313.6

265.7

265.7

245.8

245.8

189.5

189.5

145.38

C6-02

Carrier Frequency Selection

-

3

7

3

7

3

7

3

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

4.2

5.7

5.7

7

7

9.8

9.8

13.3

E2-02

(E4-02)

Motor Rated Slip

Hz

3

2.7

2.7

2.7

2.7

1.5

1.5

1.3

E2-03

(E4-03)

Motor No-Load Current

A

1.5

1.9

1.9

2.3

2.3

2.6

2.6

4

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

6.495

4.36

4.36

3.333

3.333

1.595

1.595

1.152

E2-06

(E4-06)

Motor Leakage Inductance

%

18.7

19

19

19.3

19.3

18.2

18.2

15.5

E2-10

(E4-10)

Motor Iron Loss

W

77

105

105

130

130

193

193

263

E5-01

PM Motor Code Selection

-

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

0.5

0.5

0.5

0.5

0.5

0.5

0.8

0.8

L2-03

Minimum Baseblock Time

s

0.5

0.5

0.5

0.6

0.6

0.7

0.7

0.8

L2-04

Powerloss V/f Recovery Ramp Time

s

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

L2-05

Undervoltage Detection Lvl (Uv1)

-

380

380

380

380

380

380

380

380

L3-02

Stall Prevent Level during Accel

%

150

120

150

120

150

120

150

120

L3-06

Stall Prevent Level during Run

%

150

120

150

120

150

120

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.145

0.145

0.145

0.154

0.154

0.168

0.168

0.175

L8-02

Overheat Alarm Level

°C

90

90

115

115

110

110

120

120

L8-09

Output Ground Fault Detection

-

0

0

0

0

0

0

0

0

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

10

10

10

n3-02

HSB Current Limit Level

%

150

120

150

120

150

120

150

120

n5-02

Motor Inertia Acceleration Time

s

0.145

0.145

0.145

0.154

0.154

0.168

0.168

0.175

 

No. 1

Name

Unit

Default

-

Drive Model

-

4023

4031

4038

4044

C6-01

Normal / Heavy Duty Selection

-

HD

ND

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

0

1

o2-04

Drive Model (KVA) Selection

Hex.

9A

REV:A: 9C

REV:B: 19C 2

REV:A: 9D

REV:B: 19D 2

9E

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

7.5

11

11

15

15

18.5

18.5

22

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

100

100

b3-06

Speed Estimation Current Level 1

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

1000

1000

1000

1000

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

145.38

140.88

140.88

126.26

126.26

115.74

115.74

103.58

C6-02

Carrier Frequency Selection

-

3

7

3

7

3

7

3

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

13.3

19.9

19.9

26.5

26.5

32.9

32.9

38.6

E2-02

(E4-02)

Motor Rated Slip

Hz

1.3

1.7

1.7

1.6

1.6

1.67

1.67

1.7

E2-03

(E4-03)

Motor No-Load Current

A

4

5.6

5.6

7.6

7.6

7.8

7.8

9.2

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

1.152

0.922

0.922

0.55

0.55

0.403

0.403

0.316

E2-06

(E4-06)

Motor Leakage Inductance

%

15.5

19.6

19.6

17.2

17.2

20.1

20.1

23.5

E2-10

(E4-10)

Motor Iron Loss

W

263

385

385

440

440

508

508

586

E5-01

PM Motor Code Selection

-

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

1

1

2

2

2

2

2

2

L2-03

Minimum Baseblock Time

s

0.8

0.9

0.9

1

1

1

1

1

L2-04

Powerloss V/f Recovery Ramp Time

s

0.3

0.3

0.3

0.6

0.6

0.6

0.6

0.6

L2-05

Undervoltage Detection Lvl (Uv1)

-

380

380

380

380

380

380

380

380

L3-02

Stall Prevent Level during Accel

%

150

120

150

120

150

120

150

120

L3-06

Stall Prevent Level during Run

%

150

120

150

120

150

120

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.175

0.265

0.265

0.244

0.244

0.317

0.317

0.355

L8-02

Overheat Alarm Level

°C

120

120

120

120

120

120

125

125

L8-09

Output Ground Fault Detection

-

0

0

1

1

1

1

1

1

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

10

10

10

n3-02

HSB Current Limit Level

%

150

120

150

120

150

120

150

120

n5-02

Motor Inertia Acceleration Time

s

0.175

0.265

0.265

0.244

0.244

0.317

0.317

0.355

1
 

No. 1

Name

Unit

Default

-

Drive Model

-

4060

C6-01

Normal / Heavy Duty Selection

-

HD

ND

0

1

o2-04

Drive Model (KVA) Selection

Hex.

9F

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

22

30

b3-04

V/f Gain during Speed Search

%

100

100

b3-06

Speed Estimation Current Level 1

-

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

103.58

92.54

C6-02

Carrier Frequency Selection

-

3

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

38.6

52.3

E2-02

(E4-02)

Motor Rated Slip

Hz

1.7

1.8

E2-03

(E4-03)

Motor No-Load Current

A

9.2

10.9

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

0.316

0.269

E2-06

(E4-06)

Motor Leakage Inductance

%

23.5

20.7

E2-10

(E4-10)

Motor Iron Loss

W

586

750

E5-01

PM Motor Code Selection

-

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

2

2

L2-03

Minimum Baseblock Time

s

1

1.1

L2-04

Powerloss V/f Recovery Ramp Time

s

0.6

0.6

L2-05

Undervoltage Detection Lvl (Uv1)

-

380

380

L3-02

Stall Prevent Level during Accel

%

150

120

L3-06

Stall Prevent Level during Run

%

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.355

0.323

L8-02

Overheat Alarm Level

°C

115

115

L8-09

Output Ground Fault Detection

-

1

1

n1-03

Hunting Prevention Time Constant

ms

10

10

n3-02

HSB Current Limit Level

%

150

120

n5-02

Motor Inertia Acceleration Time

s

0.355

0.323

1

Parameters within parentheses are for motor 2.

2

The value is different for different drive hardware revisions. The “REV” column on the nameplate on the right side of the drive identifies the hardware revision.