No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-01

(0750)

PM Auto-Tuning Selection

Sets the type of Auto-Tuning for PM motors.

0
Manual Entry w/ Motor Data Sheet
 
1
Stationary (Ld, Lq, R)
 
2
Stationary (R Only)
 
4
Rotational (Ld, Lq, R, back-EMF)
 
5
High Frequency Injection
 

0

(Determined by A1-02)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-02

(0751)

PM Motor Code Selection

If the drive is operating an SMRD, SMRA, or SSR1 series Yaskawa PM motor, enter the PM motor code in to align with the rotation speed and motor output.

Determined by A1-02 and o2-04

(0000 - FFFF)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-03

(0752)

PM Motor Type

Sets the type of PM motor the drive will operate.

0
IPM motor
 
1
SPM motor
 

1

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-04

(0730)

PM Motor Rated Power

Uses the units set in o1-58 [Motor Power Unit Selection] to set the PM motor rated output power.

Determined by o2-04, C6-01

(0.00 - 650.00 kW)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-05

(0732)

PM Motor Rated Voltage

Sets the rated voltage (V) of the motor.

200 V Class: 200.0 V,

400 V Class: 400.0 V

(200 V Class: 0.0 - 255.0 V, 400 V Class: 0.0 - 510.0 V)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-06

(0733)

PM Motor Rated Current

Sets the rated current (A) of the motor.

Determined by o2-04

(10% to 200% of the drive rated current)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-07

(0753)

PM Motor Base Frequency

Sets the base frequency (Hz) of the motor.

87.5 Hz

(0.0 - 590.0 Hz)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-08

(0734)

Number of PM Motor Poles

Sets the number of motor poles.

6

(2 - 120)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-09

(0731)

PM Motor Base Speed

Sets the motor base speed (min-1 (r/min)).

1750 min-1 (r/min)

(0 - 34500 min-1 (r/min))

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-10

(0754)

PM Motor Stator Resistance

Sets the stator resistance for each motor phase.

Note:

This parameter does not set line-to-line resistance.

Determined by T2-02

(0.000 - 65.000 Ω)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-11

(0735)

PM Motor d-Axis Inductance

Sets the d-axis inductance of the motor on a per phase basis.

Determined by T2-02

(0.00 - 600.00 mH)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-12

(0736)

PM Motor q-Axis Inductance

Sets the q-Axis inductance of the motor on a per phase basis.

Determined by T2-02

(0.00 - 600.00 mH)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-13

(0755)

Back-EMF Units Selection

Sets the units that the drive uses to set the induced voltage constant.

0
mV/(rev/min)
 
1
mV/(rad/sec)
 

1

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-14

(0737)

Back-EMF Voltage Constant (Ke)

Sets the motor induced voltage constant (Ke).

Determined by T2-13

(0.0 - 2000.0)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T2-15

(0756)

Pull-In Current Level

Sets the level of the pull-in current as a percentage of E5-03 [PM Motor Rated Current (FLA)]. Usually it is not necessary to change this setting.

30%

(0 - 120%)

Details