No.

(Hex.)

Name

Description

Default

(Range)

Ref.

b6-01

(01B6)

Dwell Reference at Start

Sets the output frequency that the drive will hold momentarily when the motor starts.

0.0

(Determined by A1-02)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

b6-02

(01B7)

Dwell Time at Start

Sets the length of time that the drive will hold the output frequency when the motor starts.

0.0 s

(0.0 - 10.0 s)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

b6-03

(01B8)

Dwell Reference at Stop

Sets the output frequency that the drive will hold momentarily when ramping to stop the motor.

0.0

(Determined by A1-02)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

b6-04

(01B9)

Dwell Time at Stop

Sets the length of time for the drive to hold the output frequency when ramping to stop the motor.

0.0 s

(0.0 - 10.0 s)

Details