No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-00

(0700)

Motor 1/Motor 2 Selection

Sets which motor to tune when motor 1/2 switching is enabled.

You can only use the keypad to set this parameter. You cannot use external input terminals to set it.

Note:

This parameter is enabled when H1-xx = 16 [Motor 2 Selection] is set. When H1-xx ≠ 16 the keypad will not show this parameter.

1
Motor 1

Auto-Tuning automatically sets parameters E1-xx and E2-xx for motor 1.

2
Motor 2

Auto-Tuning automatically sets parameters E3-xx and E4-xx for motor 2. Make sure that you connect motor 2 to the drive for Auto-Tuning.

1

(1, 2)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-01

(0701)

Auto-Tuning Mode Selection

Sets the type of Auto-Tuning.

0
Rotational Auto-Tuning
 
1
Stationary Auto-Tuning 1
 
2
Stationary Line-Line Resistance
 

Determined by A1-02

(Determined by A1-02)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-02

(0702)

Motor Rated Power

Uses the units set in o1-58 [Motor Power Unit Selection] to set the motor rated output power.

Determined by o2-04, C6-01

(0.00 - 650.00 kW)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-03

(0703)

Motor Rated Voltage

Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output motors.

Determined by o2-04, C6-01

(200 V Class: 0.0 - 255.5 V, 400 V Class: 0.0 - 511.0 V)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-04

(0704)

Motor Rated Current

Sets the rated current (A) of the motor.

Determined by o2-04

(10% to 200% of the drive rated current)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-05

(0705)

Motor Base Frequency

Sets the base frequency (Hz) of the motor.

60.0 Hz

(0.0 - 590.0 Hz)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-06

(0706)

Number of Motor Poles

Sets the number of motor poles.

4

(2 to 120)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-07

(0707)

Motor Base Speed

Sets the motor base speed for Auto-Tuning (min-1 (r/min)).

1750 min-1 (r/min)

(0 - 35400 min-1 (r/min))

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-09

(0709)

Motor No-Load Current

Sets the no-load current of the motor.

-

(0A - T1-04; max. of 2999.9)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-10

(070A)

Motor Rated Slip Frequency

Sets motor rated slip.

-

(0.000 - 20.000 Hz)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-11

(070B)

Motor Iron Loss

Sets the iron loss to calculate the energy-saving coefficient.

Determined by E2-10 or E4-10

(0 - 65535 W)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-12

(0BDB)

Test Mode Selection

Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate the motor with a light load attached after Stationary Auto-Tuning is complete, enable this parameter.

Note:

You must first set T1-10 = 0 [Motor Rated Slip Frequency = 0 Hz] to enable this parameter.

0
No
 
1
Yes
 

0

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

T1-13

(0BDC)

No-load voltage

Sets the no-load voltage of the motor. When the no-load voltage at rated speed is available, for example on the motor test report, set the voltage in this parameter. If the no-load voltage is not available, do not change this parameter.

Note:

To get the same qualities as a Yaskawa 1000-series drive or previous series drive, set this parameter = T1-03 [Motor Rated Voltage].

T1-03 × 0.9

(200 V Class: 0.0 - 255.0 V, 400 V Class: 0.0 - 510.0 V)

Details