YASKAWA AC Drive GA700 High Performance Type Technical Manual
No. 1
Name
Unit
Default
-
Drive Model
2001
2002
2004
2006
C6-01
Normal / Heavy Duty Selection
HD
ND
0
1
o2-04
Drive Model (KVA) Selection
Hex.
60
61
62
63
E2-11
(E4-11, E5-02)
Motor Rated Power
kW
0.1
0.2
0.4
0.75
1.1
b3-04
V/f Gain during Speed Search
%
100
b3-06
Speed Estimation Current Level 1
0.5
b3-08
Speed Estimation ACR P Gain
b3-26
Direction Determination Level
1000
b8-03
Energy Saving Filter Time
s
b8-04
Energy Saving Coefficient Value
481.7
356.9
288.2
223.7
196.6
C6-02
Carrier Frequency Selection
4
7
E2-01
(E4-01)
Motor Rated Current (FLA)
A
0.6
1.9
3.3
4.9
E2-02
(E4-02)
Motor Rated Slip
Hz
2.5
2.6
2.9
E2-03
(E4-03)
Motor No-Load Current
0.8
1.2
1.8
2.3
E2-05
(E4-05)
Motor Line-to-Line Resistance
Ω
35.98
20.56
9.842
5.156
3.577
E2-06
(E4-06)
Motor Leakage Inductance
21.6
20.1
18.2
13.8
18.5
E2-10
(E4-10)
Motor Iron Loss
W
6
11
14
26
38
E5-01
PM Motor Code Selection
FFFF
L2-02
Power Loss Ride Through Time
L2-03
Minimum Baseblock Time
0.3
L2-04
Powerloss V/f Recovery Ramp Time
L2-05
Undervoltage Detection Lvl (Uv1)
190
L3-02
Stall Prevent Level during Accel
150
120
L3-06
Stall Prevent Level during Run
L3-24
Motor Accel Time @ Rated Torque
0.178
0.142
L8-02
Overheat Alarm Level
°C
115
L8-09
Output Ground Fault Detection
n1-03
Hunting Prevention Time Constant
ms
10
n3-02
HSB Current Limit Level
n5-02
Motor Inertia Acceleration Time
2008
2010
2012
2018
64
65
66
67
1.5
2.2
3.0
3.7
169.4
156.8
136.4
122.9
3
6.2
8.5
11.4
2.7
2.73
2.8
4.5
1.997
1.601
1.034
0.771
18.4
19
19.6
53
77
91
112
0.166
0.145
0.154
110
2021
2030
2042
2056
68
6A
6B
6D
5.5
7.5
15
94.75
72.69
70.44
63.13
26.6
39.7
1.3
1.7
1.6
5.1
8
11.2
15.2
0.399
0.288
0.23
0.138
15.5
19.5
17.2
172
262
245
272
2
0.7
0.9
0.168
0.175
0.265
0.244
105
125
2070
2082
6E
6F
22
57.87
51.79
65.8
77.2
1.67
15.7
0.101
0.079
505
538
0.317
0.355
135
Parameters within parentheses are for motor 2.