No. (Hex.) Name Description Default (Range) Ref. H1-01 (0438) Terminal S1 Function Selection Sets the function for MFDI terminal S1. Note: The default setting is F when you initialize the drive for 3-Wire Initialization [A1-03 = 3330]. 40 (1 - 1FF) Details No. (Hex.) Name Description Default (Range) Ref. H1-02 (0439) Terminal S2 Function Selection Sets the function for MFDI terminal S2. Note: The default setting is F when you initialize the drive for 3-Wire Initialization [A1-03 = 3330]. 41 (1 - 1FF) Details No. (Hex.) Name Description Default (Range) Ref. H1-03 (0400) Terminal S3 Function Selection Sets the function for MFDI terminal S3. 24 (0 - 1FF) Details No. (Hex.) Name Description Default (Range) Ref. H1-04 (0401) Terminal S4 Function Selection Sets the function for MFDI terminal S4. 14 (0 - 1FF) Details No. (Hex.) Name Description Default (Range) Ref. H1-05 (0402) Terminal S5 Function Selection Sets the function for MFDI terminal S5. Note: The default setting is 0 when the drive is initialized for 3-Wire Initialization [A1-03 = 3330]. 3 (0 - 1FF) Details No. (Hex.) Name Description Default (Range) Ref. H1-06 (0403) Terminal S6 Function Selection Sets the function for MFDI terminal S6. Note: The default setting is 3 when the drive is initialized for 3-Wire Initialization [A1-03 = 3330]. 4 (0 - 1FF) Details No. (Hex.) Name Description Default (Range) Ref. H1-07 (0404) Terminal S7 Function Selection Sets the function for MFDI terminal S7. Note: The default setting is 4 when the drive is initialized for 3-Wire Initialization [A1-03 = 3330]. 6 (0 - 1FF) Details No. (Hex.) Name Description Default (Range) Ref. H1-21 (0B70) Terminal S1 Function Selection 2 Sets the second function for MFDI terminal S1. F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-22 (0B71) Terminal S2 Function Select 2 Sets the second function for MFDI terminal S2. F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-23 (0B72) Terminal S3 Function Selection 2 Sets the second function for MFDI terminal S3. F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-24 (0B73) Terminal S4 Function Selection 2 Sets the second function for MFDI terminal S4. F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-25 (0B74) Terminal S5 Function Selection 2 Sets the second function for MFDI terminal S5. F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-26 (0B75) Terminal S6 Function Selection 2 Sets the second function for MFDI terminal S6. F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-27 (0B76) Terminal S7 Function Selection 2 Sets the second function for MFDI terminal S7. F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-40 (0B54) Mbus Reg 15C0h bit0 Input Func Sets MFDI function to set to bit 0 of the MEMOBUS register 15C0 (Hex.). F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-41 (0B55) Mbus Reg 15C0h bit1 Input Func Sets MFDI function to set to bit 1 of the MEMOBUS register 15C0 (Hex.). F (1 - 19F) Details No. (Hex.) Name Description Default (Range) Ref. H1-42 (0B56) Mbus Reg 15C0h bit2 Input Func Sets MFDI function to set to bit 2 of the MEMOBUS register 15C0 (Hex.). F (1 - 19F) Details