Jump to main content

Three-Phase 200 V Class

 

No. 1

Name

Unit

Default

-

Drive Model

-

2001

2002

2004

2006

C6-01

Normal / Heavy Duty Selection

-

HD

ND

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

0

1

o2-04

Drive Model (KVA) Selection

Hex.

60

61

62

63

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

0.1

0.2

0.2

0.4

0.4

0.75

0.75

1.1

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

100

100

b3-06

Speed Estimation Current Level 1

-

1

1

1

1

1

1

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

1000

1000

1000

1000

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

481.7

356.9

356.9

288.2

288.2

223.7

223.7

196.6

C6-02

Carrier Frequency Selection

-

4

7

4

7

4

7

4

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

0.6

1.1

1.1

1.9

1.9

3.3

3.3

4.9

E2-02

(E4-02)

Motor Rated Slip

Hz

2.5

2.6

2.6

2.9

2.9

2.5

2.5

2.6

E2-03

(E4-03)

Motor No-Load Current

A

0.4

0.8

0.8

1.2

1.2

1.8

1.8

2.3

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

35.98

20.56

20.56

9.842

9.842

5.156

5.156

3.577

E2-06

(E4-06)

Motor Leakage Inductance

%

21.6

20.1

20.1

18.2

18.2

13.8

13.8

18.5

E2-10

(E4-10)

Motor Iron Loss

W

6

11

11

14

14

26

26

38

E5-01

PM Motor Code Selection

-

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

L2-03

Minimum Baseblock Time

s

0.2

0.3

0.2

0.3

0.2

0.3

0.3

0.4

L2-04

Powerloss V/f Recovery Ramp Time

s

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

L2-05

Undervoltage Detection Lvl (Uv1)

-

190

190

190

190

190

190

190

190

L3-02

Stall Prevent Level during Accel

%

150

120

150

120

150

120

150

120

L3-06

Stall Prevent Level during Run

%

150

120

150

120

150

120

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.178

0.178

0.178

0.178

0.178

0.142

0.142

0.142

L8-02

Overheat Alarm Level

°C

115

115

115

115

115

115

120

120

L8-09

Output Ground Fault Detection

-

0

0

0

0

0

0

0

0

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

10

10

10

n3-02

HSB Current Limit Level

1

150

120

150

120

150

120

150

120

n5-02

Motor Inertia Acceleration Time

s

0.178

0.178

0.178

0.142

0.178

0.142

0.142

0.142

 
 

No. 1

Name

Unit

Default

-

Drive Model

-

2008

2010

2012

2018

C6-01

Normal / Heavy Duty Selection

-

HD

ND

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

0

1

o2-04

Drive Model (KVA) Selection

Hex.

64

65

66

67

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

1.1

1.5

1.5

2.2

2.2

3.0

3.0

3.7

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

100

100

b3-06

Speed Estimation Current Level 1

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

1000

1000

1000

1000

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

196.6

169.4

169.4

156.8

156.8

136.4

136.4

122.9

C6-02

Carrier Frequency Selection

-

3

7

3

7

3

7

3

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

4.9

6.2

6.2

8.5

8.5

11.4

11.4

14

E2-02

(E4-02)

Motor Rated Slip

Hz

2.6

2.6

2.6

2.9

2.9

2.7

2.7

2.73

E2-03

(E4-03)

Motor No-Load Current

A

2.3

2.8

2.8

3

3

3.7

3.7

4.5

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

3.577

1.997

1.997

1.601

1.601

1.034

1.034

0.771

E2-06

(E4-06)

Motor Leakage Inductance

%

18.5

18.5

18.5

18.4

18.4

19

19

19.6

E2-10

(E4-10)

Motor Iron Loss

W

38

53

53

77

77

91

91

112

E5-01

PM Motor Code Selection

-

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

0.3

0.3

0.3

0.3

0.5

0.5

1

1

L2-03

Minimum Baseblock Time

s

0.4

0.4

0.4

0.5

0.5

0.5

0.5

0.6

L2-04

Powerloss V/f Recovery Ramp Time

s

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

L2-05

Undervoltage Detection Lvl (Uv1)

-

190

190

190

190

190

190

190

190

L3-02

Stall Prevent Level during Accel

%

150

120

150

120

150

120

150

120

L3-06

Stall Prevent Level during Run

%

150

120

150

120

150

120

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.142

0.166

0.166

0.145

0.145

0.145

0.145

0.154

L8-02

Overheat Alarm Level

°C

110

110

110

110

110

110

115

115

L8-09

Output Ground Fault Detection

-

0

0

0

0

0

0

0

0

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

10

10

10

n3-02

HSB Current Limit Level

1

150

120

150

120

150

120

150

120

n5-02

Motor Inertia Acceleration Time

s

0.142

0.166

0.166

0.145

0.145

0.145

0.145

0.154

 

No. 1

Name

Unit

Default

-

Drive Model

-

2021

2030

2042

2056

C6-01

Normal / Heavy Duty Selection

-

HD

ND

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

0

1

o2-04

Drive Model (KVA) Selection

Hex.

68

6A

6B

6D

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

3.7

5.5

5.5

7.5

7.5

11

11

15

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

100

100

b3-06

Speed Estimation Current Level 1

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

1000

1000

1000

1000

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

122.9

94.75

94.75

72.69

72.69

70.44

70.44

63.13

C6-02

Carrier Frequency Selection

-

3

7

3

7

3

7

3

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

14

19.6

19.6

26.6

26.6

39.7

39.7

53

E2-02

(E4-02)

Motor Rated Slip

Hz

2.73

1.5

1.5

1.3

1.3

1.7

1.7

1.6

E2-03

(E4-03)

Motor No-Load Current

A

4.5

5.1

5.1

8

8

11.2

11.2

15.2

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

0.771

0.399

0.399

0.288

0.288

0.23

0.23

0.138

E2-06

(E4-06)

Motor Leakage Inductance

%

19.6

18.2

18.2

15.5

15.5

19.5

19.5

17.2

E2-10

(E4-10)

Motor Iron Loss

W

112

172

172

262

262

245

245

272

E5-01

PM Motor Code Selection

-

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

1

1

1

1

1

1

2

2

L2-03

Minimum Baseblock Time

s

0.6

0.7

0.7

0.8

0.8

0.9

0.9

1

L2-04

Powerloss V/f Recovery Ramp Time

s

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.6

L2-05

Undervoltage Detection Lvl (Uv1)

-

190

190

190

190

190

190

190

190

L3-02

Stall Prevent Level during Accel

%

150

120

150

120

150

120

150

120

L3-06

Stall Prevent Level during Run

%

150

120

150

120

150

120

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.154

0.168

0.168

0.175

0.175

0.265

0.265

0.244

L8-02

Overheat Alarm Level

°C

115

115

105

105

115

115

125

125

L8-09

Output Ground Fault Detection

-

0

0

1

1

1

1

1

1

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

10

10

10

n3-02

HSB Current Limit Level

1

150

120

150

120

150

120

150

120

n5-02

Motor Inertia Acceleration Time

s

0.154

0.168

0.168

0.175

0.175

0.265

0.265

0.244

 

No. 1

Name

Unit

Default

-

Drive Model

-

2070

2082

C6-01

Normal / Heavy Duty Selection

-

HD

ND

HD

ND

0

1

0

1

o2-04

Drive Model (KVA) Selection

Hex.

6E

6F

E2-11

(E4-11, E5-02)

Motor Rated Power

kW

15

18.5

18.5

22

b3-04

V/f Gain during Speed Search

%

100

100

100

100

b3-06

Speed Estimation Current Level 1

-

0.5

0.5

0.5

0.5

b3-08

Speed Estimation ACR P Gain

-

0.5

0.5

0.5

0.5

b3-26

Direction Determination Level

-

1000

1000

1000

1000

b8-03

Energy Saving Filter Time

s

0.5

0.5

0.5

0.5

b8-04

Energy Saving Coefficient Value

-

63.13

57.87

57.87

51.79

C6-02

Carrier Frequency Selection

-

3

7

3

7

E2-01

(E4-01)

Motor Rated Current (FLA)

A

53

65.8

65.8

77.2

E2-02

(E4-02)

Motor Rated Slip

Hz

1.6

1.67

1.67

1.7

E2-03

(E4-03)

Motor No-Load Current

A

15.2

15.7

15.7

18.5

E2-05

(E4-05)

Motor Line-to-Line Resistance

Ω

0.138

0.101

0.101

0.079

E2-06

(E4-06)

Motor Leakage Inductance

%

17.2

15.7

20.1

19.5

E2-10

(E4-10)

Motor Iron Loss

W

272

505

505

538

E5-01

PM Motor Code Selection

-

FFFF

FFFF

FFFF

FFFF

L2-02

Power Loss Ride Through Time

s

2

2

2

2

L2-03

Minimum Baseblock Time

s

1

1

1

1

L2-04

Powerloss V/f Recovery Ramp Time

s

0.6

0.6

0.6

0.6

L2-05

Undervoltage Detection Lvl (Uv1)

-

190

190

190

190

L3-02

Stall Prevent Level during Accel

%

150

120

150

120

L3-06

Stall Prevent Level during Run

%

150

120

150

120

L3-24

Motor Accel Time @ Rated Torque

s

0.244

0.317

0.317

0.355

L8-02

Overheat Alarm Level

°C

120

120

135

135

L8-09

Output Ground Fault Detection

-

1

1

1

1

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

n3-02

HSB Current Limit Level

%

150

120

150

120

n5-02

Motor Inertia Acceleration Time

s

0.244

0.317

0.317

0.355

1

Parameters within parentheses are for motor 2.