YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
n6-01
(0570)
Online Tuning Selection
Sets the type of motor data that Online Tuning uses for OLV control.
The drive adjusts the motor line-to-line resistance during run.
The drive adjusts the output voltage during run.
Setting 2 is enabled only when b8-01 = 0 [Energy Saving Control Selection = Disabled].
0
(0 - 2)
Details
n6-05
(05C7)
Expert
Online Tuning Gain
Sets the compensation gain when n6-01 = 2 [Online Tuning Selection = Voltage Correction Tuning]. Usually it is not necessary to change this parameter.
1.0
(0.1 - 50.0)