No.

(Hex.)

Name

Description

Default

(Range)

Ref.

L7-01

(04A7)

RUN

Forward Torque Limit

Sets the torque limit value for forward motoring as a percentage, where motor rated torque is the 100% value.

200%

(0 - 300%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

L7-02

(04A8)

RUN

Reverse Torque Limit

Sets the torque limit value for reversed motoring as a percentage, where motor rated torque is the 100% value.

200%

(0 - 300%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

L7-03

(04A9)

RUN

Forward Regenerative Trq Limit

Sets the torque limit value for forward regenerative conditions as a percentage of the motor rated torque.

200%

(0 - 300%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

L7-04

(04AA)

RUN

Reverse Regenerative Trq Limit

Sets the torque limit value for reversed regenerative conditions as a percentage of the motor rated torque.

200%

(0 - 300%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

L7-06

(04AC)

Torque Limit Integral Time

Sets the integral time constant for the torque limit function.

200 ms

(5 - 10000 ms)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

L7-07

(04C9)

Torque Limit during Accel/Decel

Sets the torque limit function during acceleration and deceleration.

0
Proportional only
 
1
Proportional & Integral control
 

0

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

L7-16

(044D)

Torque Limit Process at Start

Assigns a time filter to allow the torque limit to build at start.

0
Disabled
 
1
Enabled
 

1

(0, 1)

Details