Jump to main content

n1: Hunting Prevention

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n1-01

(0580)

Hunting Prevention Selection

Sets the function to prevent hunting.

Note:

When you replace a V1000-series drive with a GA500 drive, set n1-01 = 1 [Hunting Prevention Selection = Enabled].

0
Disable
 
1
Enabled
 

0

( 0, 1 )

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n1-02

(0581)

Expert

Hunting Prevention Gain Setting

Sets the performance of the hunting prevention function. Usually it is not necessary to change this parameter.

1.00

(0.00 - 2.50)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n1-03

(0582)

Expert

Hunting Prevention Time Constant

Sets the primary delay time constant of the hunting prevention function. Usually it is not necessary to change this parameter.

Determined by o2-04

(0 - 500 ms)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n1-05

(0530)

Expert

Hunting Prevent Gain in Reverse

Sets the performance of the hunting prevention function. This parameter adjusts Reverse run. Usually it is not necessary to change this parameter.

0.00

(0.00 - 2.50)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n1-13

(1B59)

Expert

DC Bus Stabilization Control

Sets the oscillation suppression function for the DC bus voltage.

0
Disabled
 
1
Enabled
 

0

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n1-14

(1B5A)

Expert

DC Bus Stabilization Time

Adjusts the responsiveness of the oscillation suppression function for the DC bus voltage. Set n1-13 = 1 [DC Bus Stabilization Control = Enabled] to enable this parameter.

100.0 ms

(50.0 - 500.0 ms)

Details