Jump to main content

E4: Motor 2 Parameters

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-01

(0321)

Motor 2 Rated Current

Sets the motor rated current for motor 2 in amps.

Determined by o2-04, C6-01

(10% to 200% of the drive rated current)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-02

(0322)

Motor 2 Rated Slip

Sets the motor rated slip for motor 2.

Determined by o2-04, C6-01

(0.000 - 20.000 Hz)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-03

(0323)

Motor 2 Rated No-Load Current

Sets the no-load current for motor 2 in amps when operating at the rated frequency and the no-load voltage.

Determined by o2-04, C6-01

(0 to E4-01)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-04

(0324)

Motor 2 Motor Poles

Sets the number of poles for motor 2.

4

(2 - 120)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-05

(0325)

Motor 2 Line-to-Line Resistance

Sets the line-to-line resistance for the motor 2 stator windings.

Determined by o2-04, C6-01

(0.000 - 65.000 Ω)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-06

(0326)

Motor 2 Leakage Inductance

Sets the voltage drop from motor 2 leakage inductance as a percentage of Motor Rated Voltage when motor 2 operates at the rated frequency and rated current.

Determined by o2-04, C6-01

(0.0 - 60.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-07

(0343)

Motor 2 Saturation Coefficient 1

Sets the motor 2 iron-core saturation coefficient at 50% of the magnetic flux.

0.50

(0.00 - 0.50)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-08

(0344)

Motor 2 Saturation Coefficient 2

Sets the motor 2 iron-core saturation coefficient at 75% of the magnetic flux.

0.75

(E4-07 - 0.75)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-09

(033F)

Expert

Motor 2 Mechanical Loss

Sets the mechanical loss of motor 2. It is set as a percentage of E4-11 [Motor 2 Rated Power]. Usually it is not necessary to change this setting.

0.0%

(0.0 - 10.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-10

(0340)

Motor 2 Iron Loss

Sets the motor iron loss for motor 2.

Determined by o2-04, C6-01

(0 - 65535 W)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E4-11

(0327)

Motor 2 Rated Power

Sets the motor rated power in the units from o1-58 [Motor Power Unit Selection].

Determined by o2-04, C6-01

(0.00 - 650.00 kW)

Details