Code

Name

Causes

Possible Solutions

UL3

Undertorque Detection 1

A fault occurred on the machine.

Example: There is a broken pulley belt.

Examine the machine and remove the cause of the fault

The parameters are incorrect for the load.

Adjust L6-02 [Torque Detection Level 1] and L6-03 [Torque Detection Time 1].

Note:
  • The drive detects this error if the drive output current is less than the level set in L6-02 for longer than L6-03.

  • If the drive detects this error, the terminal set to H2-01 to H2-03 = 10 [MFDO Function Selection = Alarm] will activate.