dEv
|
Speed Deviation
|
The load is too heavy
|
Decrease the load.
|
|
Acceleration and deceleration times are set too short.
|
Increase the values set in C1-01 to C1-08 [Acceleration/Deceleration Time].
|
|
The dEv detection level settings are incorrect.
|
Adjust F1-10 [Speed Deviation Detection Level] and F1-11 [Speed Deviation Detect DelayTime].
|
|
The load is locked up.
|
Examine the machine.
|
|
The holding brake is stopping the motor.
|
Release the holding brake.
|
Note:
-
The drive detects this error if the difference between the detected speed and the speed reference is more than the setting of F1-10 for longer than F1-11.
-
If the drive detects this error, the terminal assigned to H2-01 to H2-04 = 10 [MFDO Function Select = Alarm] will be ON.
-
If the drive detects this error, the drive will operate the motor as specified by the stopping method set in F1-04 [Speed Deviation Detection Select].
|