oS
|
Overspeed
|
There is overshoot.
|
|
|
There is an incorrect number of PG pulses set in the drive.
|
Set H6-02 [Terminal RP Frequency Scaling] to the pulse train frequency during 100% reference (maximum motor rotation speed).
|
|
The oS detection level is set incorrectly.
|
Adjust F1-08 [Overspeed Detection Level] and F1-09 [Overspeed Detection Delay Time].
|
|
If the drive detects the fault at start or in the low speed range (10% or less) and n8-57 = 1 [HFI Overlap Selection = Enabled] for PM Control methods, the high frequency injection gain is too high.
|
|
Note:
-
The drive detects this fault if the motor speed is more than the value set in F1-08 for longer than F1-09.
-
Do a Fault Reset to clear the fault.
-
If the drive detects this fault, it will operate the motor as specified by the Stopping Method set in F1-03 [Overspeed Detection Selection].
|