Code

Name

Causes

Possible Solutions

oPE03

Multi-Function Input Setting Err

The settings for these parameters do not agree:

  • F3-10 to F3-25 [Terminal D1 to DF Function Selection]

  • H1-01 to H1-08 [Terminals S1 to S8 Function Selection]

  • H7-01 to H7-04 [Virtual Multi-Function Inputs 1 to 4]

Correct the parameter settings.

The settings for the standby mode function do not agree:

  • b8-50 = 0 [Standby Mode Selection = Disabled] and H2-xx = 65 [MFDO Function Select = Standby Output]

  • b8-50 = 1 [Enabled] and H2-xx ≠ 65

Correct the parameter settings.

The settings for MFDIs overlap.

Note:

This does not include H1-xx = 20 to 2F [MFDI Function Select = External Fault] and [Reserved].

Set the parameters correctly to prevent MFDI function overlap.

These pairs of MFDI functions are not set to Digital Inputs (H1-xx, F3-10 to F3-25, and H7-01 to H7-04) at the same time:

  • Setting values 10 [Up Command] and 11 [Down Command]

  • Setting values 75 [Up 2 Command] and 76 [Down 2 Command]

  • Setting values 42 [Run Command (2-Wire Sequence 2)] and 43 [FWD/REV (2-Wire Sequence 2)]

Set the MFDI pairs.

A minimum of two of these MFDI combinations are set to Digital Inputs (H1-xx, F3-10 to F3-25, and H7-01 to H7-04) at the same time:

  • Setting values 10 [Up Command] and 11 [Down Command]

  • Setting values 75 [Up 2 Command] and 76 [Down 2 Command]

  • Setting value A [Accel/Decel Ramp Hold]

  • Setting value 1E [Reference Sample Hold]

  • Setting values 44 to 46 [Add Offset Frequency 1 to 3 (d7-01 to d7-03)]

Remove the function settings that are not in use.

The parameter settings are enabled at the same time.

  • b5-01 [PID Mode Setting]

  • H1-xx = 10 [Up Command]

  • H1-xx = 11 [Down Command]

  • Set b5-01 = 0 [Disabled].

  • Remove the function Up/Down command settings.

These commands are set in Digital Inputs (H1-xx, F3-10 to F3-25, and H7-01 to H7-04) at the same time:

  • Setting values 61 [Speed Search from Fmax] and 62 [Speed Search from Fref]

  • Setting values 65, 66, 7A, 7B [KEB Ride-Thru 1 or 2 Activate] and 68 [High Slip Braking (HSB) Activate]

  • Setting values 16 [Motor 2 Selection] and 1A [Accel/Decel Time Selection 2]

  • Setting values 65, 66 [KEB Ride-Thru 1 Activate] and 7A, 7B [KEB Ride-Thru 2 Activate]

  • Setting values 40, 41 [Forward RUN (2-Wire), Reverse RUN (2-Wire)] and 42, 43 [Run Command (2-Wire Sequence 2), FWD/REV (2-Wire Sequence 2)]

  • Setting values 60 [DC Injection Braking Command] and 6A [Drive Enable]

  • Setting values 16 [Motor 2 Selection] and 75, 76 [Up 2 Command, Down 2 Command]

Remove the function settings that are not in use.

Settings for N.C. and N.O. input [H1-xx] for these functions were selected at the same time:

  • Setting value 15 [Fast Stop (N.O.)]

  • Setting value 17 [Fast Stop (N.C.)]

Remove one of the function settings.

These settings were entered while H1-xx = 2 [External Reference 1/2 Selection]:

  • b1-15 = 4 [Frequency Reference Selection 2 = Pulse Train Input]

  • H6-01 ≠ 0 [Terminal RP Pulse Train Function ≠ Frequency Reference]

Set H6-01 = 0.

These settings were entered while H1-xx = 2 [External Reference 1/2 Selection]:

  • b1-15 = 3 [Option PCB] or b1-16 = 3 [Run Command Selection 2 = Option PCB]

  • No option card is connected to the drive.

Connect an input option card to the drive.

These settings were entered while H1-xx = 2 [External Reference 1/2 Selection]:

  • b1-15 = 1 [Analog Input]

  • H3-02 ≠ 0 [Terminal A1 Function Selection ≠ Frequency Reference] or H3-10 ≠ 0 [Terminal A2 Function Selection ≠ Frequency Reference]

Set H3-02 = 0 or H3-10 = 0.

These parameters are set at the same time:

  • H1-xx ≠ 6A [Drive Enable]

  • H2-xx = 38 [Drive Enabled]

Correct the parameter settings.

These parameters are set at the same time:

  • H6-01 ≠ 3 [PG Speed Feedback (V/F Control)]

  • H1-xx = 7E [Reverse Rotation Identifier]

Correct the parameter settings.

These parameters are set at the same time:

  • H1-xx = 75/76 [Up 2 /Down 2 Command]

  • H3-01, H3-05, H3-09 = 1 [Terminal A1, A2, A3 Signal Level Select = -10 to +10V (Bipolar Reference)]

Remove one of the function settings.

These parameters are set at the same time:

  • H1-xx = 62 [Speed Search from Fref]

  • H5-22 = 1 [Speed Search from MODBUS = Enabled]

Remove one of the function settings.

These settings do not agree:

  • A PG-RT3 option is connected to the drive.

  • H1-xx = 16 [Motor 2 Selection] is set.

Correct the parameter settings.

Note:

The Motor Switch function is not available with the PG-RT3 option.