dv2
|
Z Pulse Noise Fault Detection
|
Noise interference along the encoder cable.
|
Isolate the encoder cable from the drive output line or a different source of electrical interference.
|
|
The encoder cable is disconnected or wired incorrectly.
|
Examine for wiring errors or disconnected wires in the encoder cable, and repair problems. Correctly ground the shielded wire of the encoder cable.
|
|
The drive is operating a motor with 24 or more poles at zero speed.
|
-
Set F1-46 = 1 [dv2 Detection Method Selection = MechanicalAngle Detection Method].
-
Increase F1-17 [Deviation 2 Detection Selection].
-
Increase F1-47 [Deviation 2 Detection Level].
Note:
If you change the setting of F1-47, the sensitivity of detection for dv2 can decrease.
|
|
The PG option or the encoder on the motor side is damaged.
|
Repair the wiring and re-energize the drive, then replace the PG option or the encoder if the problem continues.
|
|
|