oPE15
|
Torque Control Setting Error
|
More than one parameter is selecting torque control at the same time.
|
Correct the parameter settings.
|
|
Droop control and Feed Forward control are enabled at the same time that torque control is selected.
|
Correct the parameter settings.
|
|
KEB Ride-Thru 2 (N.O., N.C.) is enabled at the same time that torque control is selected.
|
Correct the parameter settings.
|
|
After a momentary power loss, drive operation will enable KEB when torque control is selected.
-
d5-01 = 1 or H1-xx = 71
-
L2-01 = 3, 4, 5 [Power Loss Ride Through Select = Kinetic Energy Backup: L2-02, Kinetic Energy Backup: CPU Power, or Kinetic Energy Backup: DecelStop]
|
Correct the parameter settings.
|
|
Optimal deceleration or overexcitation deceleration 2 is enabled at the same time that torque control is selected.
|
Correct the parameter settings.
|