oFC06
|
Option Card Error Occurred at Option Port (CN5-C)
|
A fault occurred in the option.
|
-
De-energize the drive.
-
Make sure that the option is correctly connected to the connector.
-
Re-energize the drive. If the problem continues, replace the option.
|
|
You re-energized the drive when:
-
There is an encoder option installed the drive
-
žThe drive main circuit power supply is energized
-
There is an external 24 V power supply connected to terminals PS-AC.
|
-
De-energize the drive main circuit power supply and the external 24 V power supply to terminals PS-AC.
-
After the keypad display goes out, energize the drive main circuit power supply again.
-
Supply the external 24 V power to terminals PS-AC.
|
|
When you use an encoder, de-energize the drive main circuit power supply.
|
Note:
Do a Fault Reset to clear the fault.
|