No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-01

(0300)

Input AC Supply Voltage

Sets the drive input voltage.

200 V Class: 200 V,

 
400 V Class: 400 V

 

(200 V Class: 155 to 255 V, 400 V Class: 310 to 510 V)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-03

(0302)

V/f Pattern Selection

Sets the V/f pattern for the drive and motor. You can use one of the preset patterns or you can make a custom pattern.

0
Const Trq, 50Hz base, 50Hz max

Use this constant torque pattern for general applications. This pattern is used when the load torque is constant without any rotation speed such as that used for linear conveyor systems.

1
Const Trq, 60Hz base, 60Hz max

Use this constant torque pattern for general applications. This pattern is used when the load torque is constant without any rotation speed such as that used for linear conveyor systems.

2
Const Trq, 50Hz base, 60Hz max

Use this constant torque pattern for general applications. This pattern is used when the load torque is constant without any rotation speed such as that used for linear conveyor systems.

3
Const Trq, 60Hz base, 72Hz max

Use this constant torque pattern for general applications. This pattern is used when the load torque is constant without any rotation speed such as that used for linear conveyor systems.

4
VT, 50Hz, 65% Vmid reduction

Use this derated torque pattern for torque loads proportional to three times the rotation speed. For example, fans and pumps.

5
VT, 50Hz, 50% Vmid reduction

Use this derated torque pattern for torque loads proportional to two times the rotation speed. For example, fans and pumps.

6
VT, 60 Hz, 65% Vmid reduction

Use this derated torque pattern for torque loads proportional to three times the rotation speed. For example, fans and pumps.

7
VT, 60Hz, 50% Vmid reduction

Use this derated torque pattern for torque loads proportional to two times the rotation speed. For example, fans and pumps.

8
High Trq, 50Hz, 25% Vmin boost

Use this pattern when moderate torque is necessary during start up.

9
High Trq, 50Hz, 65% Vmin boost

Use this pattern when high torque is necessary during start up.

A
High Trq, 60Hz, 25% Vmin boost

Use this pattern when moderate torque is necessary during start up.

B
High Trq, 60Hz, 65% Vmin boost

Use this pattern when high torque is necessary during start up.

C
High Freq, 60Hz base, 90Hz max

Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate at more than 60 Hz.

D
High Freq, 60Hz base, 120Hz max

Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate at more than 60 Hz.

E
High Freq, 60Hz base, 180Hz max

Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate at more than 60 Hz.

F
Custom

Set E1-04 to E1-13 [V/f Pattern for Motor 1] to set the values for this custom pattern.

Note:
  • When A1-02 = 2 [Control Method Selection = OLV], settings 0 to E are not available.

  • Set the correct V/f pattern for the application and operation area. An incorrect V/f pattern can decrease motor torque and increase current from overexcitation.

F

(Determined by A1-02)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-04

(0303)

Maximum Output Frequency

Sets the maximum output frequency for the V/f pattern.

Determined by A1-02 and E5-01

(Determined by A1-02 and E5-01)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-05

(0304)

Maximum Output Voltage

Sets the maximum output voltage for the V/f pattern.

200.0

(200 V Class: 0.0 - 255.0 V, 400 V Class: 0.0 - 510.0 V)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-06

(0305)

Base Frequency

Sets the base frequency for the V/f pattern.

Determined by A1-02 and E5-01

(0.0 - E1-04)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-07

(0306)

Mid Point A Frequency

Sets a middle output frequency for the V/f pattern.

Determined by A1-02

(0.0 - E1-04)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-08

(0307)

Mid Point A Voltage

Sets a middle output voltage for the V/f pattern.

Determined by A1-02,C6-01 and o2-04

(200 V Class: 0.0 - 255.0 V, 400 V Class: 0.0 - 510.0 V)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-09

(0308)

Minimum Output Frequency

Sets the minimum output frequency for the V/f pattern.

Determined by A1-02 and E5-01

(Determined by A1-02, E1-04, and E5-01)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-10

(0309)

Minimum Output Voltage

Sets the minimum output voltage for the V/f pattern.

Determined by A1-02

(200 V Class: 0.0 to 255.0 V, 400 V Class: 0.0 to 510.0 V)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-11

(030A)

Expert

Mid Point B Frequency

Sets a middle output frequency for the V/f pattern.

0.0 Hz

(0.0 - E1-04)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-12

(030B)

Expert

Mid Point B Voltage

Sets a middle point voltage for the V/f pattern.

0.0 V

(200 V Class: 0.0 to 255.0 V, 400 V Class: 0.0 to 510.0 V)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E1-13

(030C)

Expert

Base Voltage

Sets the base voltage for the V/f pattern.

0.0 V

(200 V Class: 0.0 - 255.0 V,400 V Class: 0.0 - 510.0 V)

Details