Jump to main content

o1: Keypad Display Selection

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-01

(0500)

RUN

User Monitor Selection

Sets the U monitor for the Drive Mode. This parameter is only available with an LED keypad.

106

(104 - 855)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-02

(0501)

RUN

Monitor Selection at Power-up

Sets the monitor item that the keypad screen shows after you energize the drive. Refer to “U: Monitors” for information about the monitor items that the keypad screen can show. This parameter is only available with an LED keypad.

1
Frequency Reference (U1-01)

 

2
Direction

 

3
Output Frequency (U1-02)

 

4
Output Current (U1-03)

 

5
User Monitor (o1-01)

Shows the monitor item selected in o1-01 [User Monitor Selection].

1

(1 - 5)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-03

(0502)

Frequency Display Unit Selection

Sets the display units for the frequency reference and output frequency.

0
0.01 Hz
 
1
0.01% (100% = E1-04)

The maximum output frequency is 100%.

Note:

Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.

  • A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]

  • A1-02 = 8: E9-02 [Maximum Speed]

2
min-1 (r/min) units

The drive uses the maximum output frequency and number of motor poles to calculate this value automatically.

3
User Units (o1-10 & o1-11)

Uses o1-10 [User Units Maximum Value] and o1-11 [User Units Decimal Position] to set the unit of measure.

Determined by A1-02

(0 - 3)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-04

(0503)

V/f Pattern Display Unit

Sets the setting unit for parameters that set the V/f pattern frequency.

0
Hz
 
1
min-1 (r/min) units

When you set o1-04 = 1, make sure that you set the number of motor poles in these parameters:

  • E2-04 [Motor Pole Count]

  • E5-04 [PM Motor Pole Count]

  • E9-08 [Motor Pole Count]

Determined by A1-02

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-05

(0504)

RUN

LCD Contrast Adjustment

Sets the contrast of the LCD display on the keypad.

5

(0 - 10)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-10

(0520)

User Units Maximum Value

Sets the value that the drive shows as the maximum output frequency.

Determined by o1-03

(1 - 60000)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-11

(0521)

User Units Decimal Position

Sets the number of decimal places for frequency reference and monitor values.

0
No Decimal Places (XXXXX)
 
1
One Decimal Places (XXXX.X)
 
2
Two Decimal Places (XXX.XX)
 
3
Three Decimal Places (XX.XXX)
 

Determined by o1-03

(0 - 3)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-24

(11AD)

RUN

Custom Monitor 1

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the first line. The registered monitor is also used for different monitor displays of bar graph, analog meter, and waveform.

101

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-25

(11AE)

RUN

Custom Monitor 2

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the second line. The registered monitor is also used for different monitor displays of bar graph and waveform.

102

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-26

(11AF)

RUN

Custom Monitor 3

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the third line. The registered monitor is also used for the monitor display of the bar graph.

103

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-27

(11B0)

RUN

Custom Monitor 4

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the fourth line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-28

(11B1)

RUN

Custom Monitor 5

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the fifth line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-29

(11B2)

RUN

Custom Monitor 6

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the sixth line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-30

(11B3)

RUN

Custom Monitor 7

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the seventh line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-31

(11B4)

RUN

Custom Monitor 8

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the eighth line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-32

(11B5)

RUN

Custom Monitor 9

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the ninth line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-33

(11B6)

RUN

Custom Monitor 10

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the 10th line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-34

(11B7)

RUN

Custom Monitor 11

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the 11th line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-35

(11B8)

RUN

Custom Monitor 12

You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-35. This parameter sets the user monitor to show on the 12th line.

0

(0,101 - 9999)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-36

(11B9)

RUN

LCD Backlight Brightness

Sets the intensity of the LCD keypad backlight.

3

(1 - 5)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-37

(11BA)

RUN

LCD Backlight ON/OFF Selection

Sets the automatic shut off function for the LCD backlight.

0
OFF
 
1
ON
 

1

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-38

(11BB)

RUN

LCD Backlight Off-Delay

Sets the time until the LCD backlight automatically turns off.

60 s

(10 - 300 s)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-39

(11BC)

RUN

Show Initial Setup Screen

Sets the function to show the LCD keypad initial setup screen each time you energize the drive. This parameter is only available with an LCD keypad.

0
No
 
1
Yes
 

1

(0, 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-40

(11BD)

RUN

Home Screen Display Selection

Sets the monitor display mode for the Home screen. This parameter is only available with an LCD keypad.

0
Custom Monitor
 
1
Bar Graph
 
2
Analog Gauge
 
3
Trend Plot
 

0

(0 - 3)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-41

(11C1)

RUN

1st Monitor Area Selection

Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a bar graph. This parameter is only available with an LCD keypad.

0
+/- Area ( - o1-42 ~ o1-42 )
 
1
+ Area ( 0 ~ o1-42 )
 

0

(0 - 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-42

(11C2)

RUN

1st Monitor Area Setting

Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a bar graph. This parameter is only available with an LCD keypad.

100.0%

(0.0 - 100.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-43

(11C3)

RUN

2nd Monitor Area Selection

Selects the horizontal range used to display the monitor set in o1-25 [Custom Monitor 2] as a bar graph. This parameter is only available with an LCD keypad.

0
+/- Area ( - o1-44 ~ o1-44 )
 
1
+ Area ( 0 ~ o1-44 )
 

0

(0 - 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-44

(11C4)

RUN

2nd Monitor Area Setting

Sets the horizontal axis value used to display the monitor set in o1-25 [Custom Monitor 2] as a bar graph. This parameter is only available with an LCD keypad.

100.0%

(0.0 - 100.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-45

(11C5)

RUN

3rd Monitor Area Selection

Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a bar graph. This parameter is only available with an LCD keypad.

0
+/- Area ( - o1-46 ~ o1-46 )
 
1
+ Area ( 0 ~ o1-46 )
 

0

(0 - 1)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-46

(11C6)

RUN

3rd Monitor Area Setting

Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a bar graph. This parameter is only available with an LCD keypad.

100.0%

(0.0 - 100.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-47

(11C7)

RUN

Trend Plot 1 Scale Minimum Value

Sets the horizontal axis minimum value used to display the monitor set in o1-24 [Custom Monitor 1] as a trend plot. This parameter is only available with an LCD keypad.

-100.0%

(-300.0 - +299.9%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-48

(11C8)

RUN

Trend Plot 1 Scale Maximum Value

Sets the maximum value for the vertical axis used to display the monitor that was set in o1-24 [Custom Monitor 1] as a trend plot. This parameter is only available with an LCD keypad.

100.0%

(-299.9 - +300.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-49

(11C9)

RUN

Trend Plot 2 Scale Minimum Value

Sets the horizontal axis minimum value used to display the monitor set in o1-25 [Custom Monitor 2] as a trend plot. This parameter is only available with an LCD keypad.

-100.0%

(-300.0 - +299.9%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-50

(11CA)

RUN

Trend Plot 2 Scale Maximum Value

Sets the maximum value for the vertical axis used to display the monitor that was set in o1-25 [Custom Monitor 2] as a trend plot. This parameter is only available with an LCD keypad.

100.0%

(-299.9 - +300.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-51

(11CB)

RUN

Trend Plot Time Scale Setting

Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the drive automatically adjusts the data sampling time. This parameter is only available with an LCD keypad.

300 s

(1 - 3600 s)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-55

(11EE)

RUN

Analog Gauge Area Selection

Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge. This parameter is only available with an LCD keypad.

0
+/- Area ( - o1-56 ~ o1-56 )
 
1
+ Area ( 0 ~ o1-56 )
 

1

( 0, 1 )

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-56

(11EF)

RUN

Analog Gauge Area Setting

Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter. This parameter is only available with an LCD keypad.

100.0%

(0.0 - 100.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

o1-58

(3125)

Motor Power Unit Selection

Sets the setting unit for parameters that set the motor rated power.

0
kW

Shows the motor output in kW units.

1
HP

Shows the motor output in HP units.

0

(0, 1)

Details