Jump to main content

U8: DriveWorksEZ Monitors

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-01

(1950)

DWEZ Monitor 1

Shows DWEZ Monitor 1. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-02

(1951)

DWEZ Monitor 2

Shows DWEZ Monitor 2. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-03

(1952)

DWEZ Monitor 3

Shows DWEZ Monitor 3. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-04

(1953)

DWEZ Monitor 4

Shows DWEZ Monitor 4. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-05

(1954)

DWEZ Monitor 5

Shows DWEZ Monitor 5. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-06

(1955)

DWEZ Monitor 6

Shows DWEZ Monitor 6. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-07

(1956)

DWEZ Monitor 7

Shows DWEZ Monitor 7. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-08

(1957)

DWEZ Monitor 8

Shows DWEZ Monitor 8. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-09

(1958)

DWEZ Monitor 9

Shows DWEZ Monitor 9. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-10

(1959)

DWEZ Monitor 10

Shows DWEZ Monitor 10.

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-11

(195A)

DWEZ Version 1

Shows the Upper three digits of the user ID. When you click the setting button on the title bar of the PC tool to open the setting screen, you can confirm the user ID with the primary user ID display.

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-12

(195B)

DWEZ Version 2

Shows the lower five digits of the user ID. When you click the setting button on the title bar of the PC tool to open the setting screen, you can confirm the user ID with the primary user ID display.

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-13

(195C)

DWEZ Version 3

Shows the software ID.

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-18

(1961)

DWEZ Platform Ver

Shows the DriveWorksEZ platform version.

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-21

(1964)

DWEZ Monitor 21

Shows DWEZ Monitor 21. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-22

(1965)

DWEZ Monitor 22

Shows DWEZ Monitor 22.

The number of decimal points shown is set with Q2-21.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-23

(1966)

DWEZ Monitor 23

Shows DWEZ Monitor 23.

The number of decimal points shown is set with Q2-22.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-24

(1967)

DWEZ Monitor 24

Shows DWEZ Monitor 24.

The number of decimal points shown is set with Q2-23.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-25

(1968)

DWEZ Monitor 25

Shows DWEZ Monitor 25.

The number of decimal points shown is set with Q2-24.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-31

(196E)

DWEZ Monitor 31

Shows DWEZ Monitor 31. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-32

(196F)

DWEZ Monitor 32

Shows DWEZ Monitor 32. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-33

(1970)

DWEZ Monitor 33

Shows DWEZ Monitor 33. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-34

(1971)

DWEZ Monitor 34

Shows DWEZ Monitor 34. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-35

(1972)

DWEZ Monitor 35

Shows DWEZ Monitor 35. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-36

(1973)

DWEZ Monitor 36

Shows DWEZ Monitor 36. (Display range: 0.00% to 999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-37

(1974)

DWEZ Monitor 37

Shows DWEZ Monitor 37. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-38

(1975)

DWEZ Monitor 38

Shows DWEZ Monitor 38. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-39

(1976)

DWEZ Monitor 39

Shows DWEZ Monitor 39. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-40

(1977)

DWEZ Monitor 40

Shows DWEZ Monitor 40.

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-51

(1982)

DWEZ Monitor 51

Shows DWEZ Monitor 51. (Display range: -999.9% to +999.99%)

0.01%

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-52

(1983)

DWEZ Monitor 52

Shows DWEZ Monitor 52.

The number of decimal points shown is set with Q2-41.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-53

(1984)

DWEZ Monitor 53

Shows DWEZ Monitor 53.

The number of decimal points shown is set with Q2-42.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-54

(1985)

DWEZ Monitor 54

Shows DWEZ Monitor 54.

The number of decimal points shown is set with Q2-43.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-55

(1986)

DWEZ Monitor 55

Shows DWEZ Monitor 55.

The number of decimal points shown is set with Q2-44.

10 V = 100%

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-60

(198B)

RemoteIO Status

Shows the operation status of Remote IO as 1 (ON) and 0 (OFF). If the DriveWorksEZ MEMOBUS master active signal is ON, for example, the monitor shows U8-60 = 00000001.

bit 0
Bit 0: DriveWorksEZ MEMOBUS Master Active
 
bit 1
Not used (normal value of 0)
 
bit 2
Not used (normal value of 0)
 
bit 3
Not used (normal value of 0)
 
bit 4
Not used (normal value of 0)
 
bit 5
Not used (normal value of 0)
 
bit 6
Not used (normal value of 0)
 
bit 7
Not used (normal value of 0)
 

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-61

(198C)

RemoteDI Monitor 0-7bit

Shows the operation status of Remote DI1 to DI8 as 1 (ON) and 0 (OFF). If Remote DI1 and DI2 are ON, for example, the monitor shows U8-61 = 00000011.

bit 0
Remote DI1
 
bit 1
Remote DI2
 
bit 2
Remote DI3
 
bit 3
Remote DI4
 
bit 4
Remote DI5
 
bit 5
Remote DI6
 
bit 6
Remote DI7
 
bit 7
Remote DI8
 

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-62

(198D)

RemoteDI Monitor 8-Fbit

Shows the operation status of Remote DI9 to DI16 as 1 (ON) and 0 (OFF). If Remote DI9 and DI10 are ON, for example, the monitor shows U8-62 = 00000011.

bit 0
Remote DI9
 
bit 1
Remote DI10
 
bit 2
Remote DI11
 
bit 3
Remote DI12
 
bit 4
Remote DI13
 
bit 5
Remote DI14
 
bit 6
Remote DI15
 
bit 7
Remote DI16
 

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-63

(198E)

RemoteDO Monitor 0-7bit

Shows the operation status of Remote DO1 to DO8 as 1 (ON) and 0 (OFF). If Remote DO1 and DO2 are ON, for example, the monitor shows U8-63 = 00000011.

bit 0
Remote DO1
 
bit 1
Remote DO2
 
bit 2
Remote DO3
 
bit 3
Remote DO4
 
bit 4
Remote DO5
 
bit 5
Remote DO6
 
bit 6
Remote DO7
 
bit 7
Remote DO8
 

No signal output available

No.

(Hex.)

Name

Description

MFAO Signal Level

U8-64

(198F)

RemoteDO Monitor 8-Fbit

Shows the operation status of Remote DO9 to DO16 as 1 (ON) and 0 (OFF). If Remote DO9 and DO10 are ON, for example, the monitor shows U8-64 = 00000011.

bit 0
Remote DO9
 
bit 1
Remote DO10
 
bit 2
Remote DO11
 
bit 3
Remote DO12
 
bit 4
Remote DO13
 
bit 5
Remote DO14
 
bit 6
Remote DO15
 
bit 7
Remote DO16
 

No signal output available