No. (Hex.) Name Description Default (Range) Ref. n6-01 (0570) Online Tuning Selection Sets the type of motor data that Online Tuning uses for OLV control. 0 Disabled 1 Line-to-Line Resistance Tuning The drive adjusts the motor line-to-line resistance during run. 2 Voltage Correction Tuning The drive adjusts the output voltage during run. Note: Setting 2 is enabled only when b8-01 = 0 [Energy Saving Control Selection = Disabled]. 0 (0 - 2) Details No. (Hex.) Name Description Default (Range) Ref. n6-05 (05C7) Expert Online Tuning Gain Sets the compensation gain when n6-01 = 2 [Online Tuning Selection = Voltage Correction Tuning]. Usually it is not necessary to change this parameter. 1.0 (0.1 - 50.0) Details No. (Hex.) Name Description Default (Range) Ref. n6-11 (1B56) Expert Online Resistance Tuning Sets the responsiveness for online resistor tuning. Set this parameter to approximately 1.000 to enable the function. The function is disabled when the value is 0.000. 0.000 (0.000 - 1.000) Details