YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
C3-01
(020F)
RUN
Slip Compensation Gain
Sets the gain for the slip compensation function. Usually it is not necessary to change this setting.
When A1-02 = 4 [AOLV], you cannot change the setting while the drive is running.
Correctly set these parameters before you change the slip compensation gain:
E2-01 [Motor Rated Current (FLA)]
E2-02 [Motor Rated Slip]
E2-03 [Motor No-Load Current]
Determined by A1-02
(0.0 - 2.5)
Details
C3-02
(0210)
Slip Compensation Delay Time
Sets the slip compensation delay time when speed is unstable or when the slip compensation response is too slow. Usually it is not necessary to change this setting.
(0 - 10000 ms)
C3-03
(0211)
Slip Compensation Limit
Sets the upper limit for the slip compensation function as a percentage of the motor rated slip.
200%
(0 - 250%)
C3-04
(0212)
Slip Compensation at Regen
Sets the slip compensation function during regeneration.
The drive will not do Slip compensation during regeneration.
Slip compensation function is enabled during regeneration. Slip compensation is disabled at output frequencies of 6 Hz or less.
The drive uses E2-02 [Motor Rated Slip] to automatically calculate the frequency range where it will disable slip compensation function during regenerative operation.
0
(0 - 2)
C3-05
(0213)
Output Voltage Limit Selection
Sets the automatic reduction of motor magnetic flux when the output voltage is saturated.
(0, 1)
C3-16
(0261)
Expert
Vout Modulation Limit Start Lvl
Sets the modulation factor that starts the output voltage limit operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
90.0%
(70.0 - 90.0%)
C3-17
(0262)
Vout Modulation Limit Max Level
Sets the modulation factor used with C3-18 [Output Voltage Limit Level] for the output voltage limit operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
100.0%
(85.0 - 100.0%)
C3-18
(0263)
Output Voltage Limit Level
Sets the maximum drop width of the voltage reference when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
(50.0 - 100.0%)
C3-21
(033E)
Motor 2 Slip Compensation Gain
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to change this setting.
Correctly set these parameters before changing the slip compensation gain:
E4-01 [Motor 2 Rated Current]
E4-02 [Motor 2 Rated Slip]
E4-03 [Motor 2 Rated No-Load Current]
Determined by E3-01
C3-22
(0241)
Motor 2 Slip Comp Delay Time
Sets the slip compensation delay time for motor 2 when speed is unstable or when the slip compensation response is too slow. Usually it is not necessary to change this setting.
C3-23
(0242)
Motor 2 Slip Compensation Limit
Sets the upper limit for the slip compensation function as a percentage of the motor 2 rated slip.
C3-24
(0243)
Motor 2 Slip Comp during Regen
Sets the slip compensation during regenerative operation function for motor 2.
C3-28
(1B5B)
Adaptive Slip Control Mode
Sets the slip compensation function mode.