YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
H3-01
(0410)
Terminal A1 Signal Level Select
Sets the input signal level for MFAI terminal A1.
0
(0 - 3)
Details
H3-02
(0434)
Terminal A1 Function Selection
Sets the function for MFAI terminal A1.
(0 - 32)
H3-03
(0411)
RUN
Terminal A1 Gain Setting
Sets the gain of the analog signal input to MFAI terminal A1.
100.0%
(-999.9 - +999.9%)
H3-04
(0412)
Terminal A1 Bias Setting
Sets the bias of the analog signal input to MFAI terminal A1.
0.0%
H3-05
(0413)
Terminal A3 Signal Level Select
Sets the input signal level for MFAI terminal A3.
H3-06
(0414)
Terminal A3 Function Selection
Sets the function for MFAI terminal A3.
2
H3-07
(0415)
Terminal A3 Gain Setting
Sets the gain of the analog signal input to MFAI terminal A3.
H3-08
(0416)
Terminal A3 Bias Setting
Sets the bias of the analog signal input to MFAI terminal A3.
H3-09
(0417)
Terminal A2 Signal Level Select
Sets the input signal level for MFAI terminal A2.
H3-10
(0418)
Terminal A2 Function Selection
Sets the function for MFAI terminal A2.
H3-11
(0419)
Terminal A2 Gain Setting
Sets the gain of the analog signal input to MFAI terminal A2.
H3-12
(041A)
Terminal A2 Bias Setting
Sets the bias of the analog signal input to MFAI terminal A2.
H3-13
(041B)
Analog Input FilterTime Constant
Sets the time constant for primary delay filters on MFAI terminals.
0.03 s
(0.00 - 2.00 s)
H3-14
(041C)
Analog Input Terminal Enable Sel
Sets the enabled terminal or terminals when H1-xx = C [MFDI Function Select = Analog Terminal Enable Selection] is ON.
7
(1 - 7)
H3-16
(02F0)
Terminal A1 Offset
Sets the offset level for analog signals input to terminal A1. Usually it is not necessary to change this setting.
(-500 - +500)
H3-17
(02F1)
Terminal A2 Offset
Sets the offset level for analog signals input to terminal A2. Usually it is not necessary to change this setting.
H3-18
(02F2)
Terminal A3 Offset
Sets the offset level for analog signals input to terminal A3. Usually it is not necessary to change this setting.
H3-40
(0B5C)
Mbus Reg 15C1h Input Function
Sets the MEMOBUS AI1 function.
F
(4 - 2F)
H3-41
(0B5F)
Mbus Reg 15C2h Input Function
Sets the MEMOBUS AI2 function.
H3-42
(0B62)
Mbus Reg 15C3h Input Function
Sets the MEMOBUS AI3 function.
H3-43
(117F)
Mbus Reg Inputs FilterTime Const
Sets the time constant to apply a primary delay filter to the MEMOBUS analog input register values.
0.00 s